panel thermostat for freezer PLR400
Featues
1 Temperature control
2 Evap.Fan control
3 Automatic/Manual defrost by electric heater
4 Time/Temp.setting to end defrost
5 Re-start delay
6 Mini-sized and integrated intelligent controller
7 Applicable to the compressor of 1HP
Technical Data
1 Range of temperature:-45°C~45°C
Accuracy:±1°C
2 Cmpressor:NO.20A/250VAC
Defrost:NO.10A/250VAC
Evap.Fan:NO.8A/250VAC
Output of the outside sealed transformer:12VAC
3 sensor:2 NTC
4 Temperature of the operating environment:-10°C~60°C
Relative humidity:20%~90%(Non-condensing)
Size
Dimension:77(L)x35(W)x60(D)mm
Mounting hole dimenion:71(L)x29(W)mm
Circuit diagram
Parameter
Parameter | Function | Set range | Default |
E1 | Lower setpoint limit | -45°C~Set temp. | -35°C |
E2 | Higher setpoint limit | Set temp.~45°C | 20°C |
E3 | Temp.Hysteresis | 1~10°C | 4°C |
E4 | Comp.start delay time | 0~10Min | 2Min |
E5 | Offset on room temp. | -5~5°C | 0 |
E6 | Offset on evap.Temp. | -5~5°C | 0 |
F1 | Max.Defrost duration | 1~60Min | 20Min |
F2 | Defrost interval time | 0~24Hr | 6Hr |
F3 | Defrost termination temp. | 0~20°C | 8°C |
F4 | Display during defrost | 0=Normal display 1=Last value before defrost |
0 |
F5 | Fan start up delay after defrost end | 1~30Min | 3Min |
F0 | Defrost funciton | 1=Defrost 2=Electric heater 3=Hot gas | 1 |
Certificated