Brand Name: TEREN
Model Number: CDWC
Place of Origin: Guangdong, China (Mainland)
CDWN: Wall mount CO2 Transmitter optional with LCD or without LCD
CDWC: Wall mount CO2 Controller with LCD & keys
CDDN: Duct mount CO2 Transmitter
Applications & Features
Specifications for CDWN&CDDN
Sensor: NDIR sensor, with ABC algorithm*
Sampling Method: diffusion
Accuracy: see models
Response time: <10s (30cc/min, low airflow)
Drift: <±10ppm/year
Range: 0~2000ppm
Output: 4~20mA, 0~10V, RS485/Modbus
Load resistance: ≤500Ω (Current output),
≥2kΩ (Voltage output)
Power supply: 16~28VAC/16~36VDC
Display: Optional LCD(CDWN),with unit display
Display resolution: 1ppm
Working environment: 0~50°C, 5~95%RH (Non-condensing)
Storage temperature: -20~80℃
Housing material: fireproof ABS
Protection: IP30 (CDWN), IP65 (CDDN)
Approval: CE
*ABC algorithm: Automatic Baseline Correction, it constantly keeps track of the sensor's lowest reading over a few days interval and slowly corrects for any long term drift detected as compared to the expected fresh air value of 400 ppm CO2.
Models
Model | CDWN CDDN |
Wall mount CO2 transmitter Duct mount CO2 transmitter |
|||
Accuracy | 0 1 |
50 ppm + 5% reading 40 ppm + 3% readind |
|||
Output |
|
1 B |
4~20mA / 0~10VDC 4~20mA / 0~10VDC , RS485/Modbus |
||
Display (CDWN) |
0 1 |
N/A LCD |
Specifications for CDWC
Sensor: NDIR sensor, with ABC algorithm*
Sampling Method: diffusion
Temp. Compensation: CDWC0: 10-40℃; CDWC1: 0-50℃
Response time: <120s (30cc/min, low airflow)
Drift: <±10ppm/year
Range: 0~2000ppm (measure range 400~2000ppm)
Output: 2×SPST, 3A-30VDC/250VAC
Communication: optional RS485/Modbus
Power supply: 16~28VAC/16~36VDC
Display and keys: with LCD Display and 3 touch keys
Display resolution: 1ppm
Working environment: 0~50°C, 5~95%RH (Non-condensing)
Storage temperature: -20~60℃
Housing: ABS + PC
Protection: IP30
Weight: 135g
Approval: CE
*ABC algorithm: Automatic Baseline Correction, it constantly keeps track of the sensor's lowest reading over a few days interval and slowly corrects for any long term drift detected as compared to the expected fresh air value of 400 ppm CO2.
Models
Model | CDWC |
Wall mount CO2 Controller |
|
Accuracy | 0 1 |
50 ppm + 5% reading 40 ppm + 3% reading |
|
Communication | 0 1 |
N/A RS485/Modbus |
Sample Order |
Order |
OEM Order |
Three work days | 2 weeks | 3 weeks |
Port
Shenzhen, Hong Kong
Why choose us ?
♦ Specilizng in manufacturing products of HVAC for almost 10 years.
♦ Harsh process of production and strict testing system.
♦ Material could be traced.
♦ High quality with competitive price.
♦ Delivery in time.
♦ Reply in 24 hours.
Certifications
Q1: How to get the latest price?
Tell me the models, quantity, and other special requirement.
Q2: Payment terms?
100% T/T in advance.
Q3: Delivery time?
One week.
Q4: Shippment?
DHL, UPS, TNT etc.
Q5: Is OEM/ODM available?
Yes, it's available.
Q6: Warranty?
18 months.