anti corrosive automatic control water heater flow switch anti corrosive automatic control water heater flow switch

anti corrosive automatic control water heater flow switch

FOB Price:
Min.Order Quantity:
100 Piece/Pieces
Supply Ability:
200000 Piece/Pieces per Month
Port:
dongguan
Place of Origin:
Guangdong, China (Mainland)
Payment Terms:
L/C,T/T,Western Union,MoneyGram,cash
Brand:
RGP
Products Model:
W6-P2W
Share:
  • Products Details
  • Company Profile

Quick Details

  • Brand Name: RGP

    Model Number: W6-P2W

    Place of Origin: Guangdong, China (Mainland)

Packaging & Delivery

  • Packaging Details: carton
  • Delivery Detail: one week

Specifications

 

                                                                                                                                                        

  

Working principle

 

   Utilize the float with magnetic field and reed switches. One or more reed switches are placed at a specific height inside a guide tube. The changes in liquid level modify the float

position in this guide tube, so that when it reaches the switch position, it changes its status, providing an output signal for level detection.

 

   In accordance with the measured liquid temperature, pressure, specific gravity, acid and other features, select the appropriate size of the float. Follow the specifications needed to determine the purchase (or threaded mounting flange mounting, etc.), each action point, the action in the form of (normally open or normally closed) and total length.

 

General information

  1.  Switches should be installed rigidly so that float or floats are free to move as the liquid level changes.
  2.  Switches should be mounted in a tank area free of severe turbulence turbulence or protected from such turbulence by appropriate and adequate slosh shields.
  3. Vertical switch stems should be vertical for best results, but satisfactory operation is possible in most liquids with  the stem at up to a 30 degree angle from vertical.
  4.  Side mount switch stems must be mounted with arrow vertically either up or down depending on switch operation .
  5.  Care should be taken that switches are always operated within electrical ratings.
  6. Orientation for standard vertical switches can be changed from normally open to normally closed dry or vice versa by removing the float and reversing in the stem.

 

Applicaction:

1. Control of industrial processes and dosing tanks

2. Food and beverage industry

3.Level control in shipping industry

4.Chemical and textile industry

 

Our Services

 

 

 

 

 

 

Maintenance should consist of inspection to see that the float is free to move and coated with any substance , which would change its weight or volume significantly. IF this occurs, this float should be cleaned .This is easily accomplished without disturbing the installation . In addition , the stem may be wiped down to remove any build-up.The only repair possible in the field is replacement of either the float or stem . Dents or nicks on the float are usually 

of  no consequence to operation.

 

 

 

hot pp water flow alarm sensor

 

 

Related Products

 

 

Packaging & Shipping

 

 

 

 

 

 

 

Company Information

 

 

Jinhefeng  industrial electrical co., ltd is devoting to designs and manufacture the sensing switch for more than 10 years .we  have striven and now provides some of the best sensor solutions for liquid level, in addition to pressure and temperature measurement, for the most demanding float switch applications. Whether you need a single point float switch or continuous liquid level sensor, JHF Company can direct you to the proper float switch and liquid level sensor solution. Our Company offers standard float switch sensors in stock for same day shipment, and can also custom configures multiple-point float level switches in only days. 

 

 

 We manufacture float switches that stand up to harsh environments, hazardous locations and pressures,sanitary and food grade.  Many JHF float switch designs meet agency approvals like ROHS and ISO, and our sensor are widely used the food and beverage,medical equipment ,industrial equipment and etc. 

 

 

 Whether you need a float switch, continuous liquid level sensor, pressure or temperature sensor, utilized in Water and Waste Water Tanks, Food and Food Processing Equipment, HVAC, Specialty Vehicles, Medical, Marine, Washing Equipment, or any Industrial Application, let JHF provide it.

 

 

 Professional  oil gauge maker

 
  • Email to this supplier
  • To :
    Chen  |  Dongguan Jinhefeng Industrial Electrical Co., Ltd.
  • *Subject :
  • Quantity Order:
  • *Message :

  • Your message must be between 20-2000 characters
  • + Add attachments :
    Select File  (Max 2 files) 
  •  Please enter your company name:

    Please make sure your company name is entered correctly.

  • * Please enter your email address:

    Please make sure your email address is entered correctly.

  • * Please enter your mobile phone:

    (+)   - 

    Please make sure your mobile phone is entered correctly.

Verified Supplier - Dongguan Jinhefeng Industrial Electrical Co., Ltd. Bussiness Type:  Manufacturer,Trading Company
Scale:  51 - 100 People
Country/Region:  China (Mainland)/Asia
Established:  
You May Like:
Mini reliable magnetic electrical control water flow switch

hight quality PP magnetic electrical control water flow sensor

hight quality PP magnetic electrical control liduid flow switch

Mini PP electronic magnetic control water flow switch

high stable PP electrical magnetic control air flow sensor

PP magnetic water pressure sensor liduid flow switch

PP magnetic pressure sensor water flow switch

PP magnetic pressure sensor liduid control flow switch

PP for liquid control magnetic control water flow switch