Brand Name: LUTE OR OEM
Model Number: LTLS
Place of Origin: Shandong, China (Mainland)
Screw Water Cooled Chillers, Water Chillers, Chillers, Industrial Chillers, CE Certificate Chillers
Single Compressor Units: LTLS30---LTLS200 50KW-500KW COOLING RANGE
Double Compressor Units: LTLS60-LTLS400 100KW-1000KE COOLING RANGE
DESIGN:1.Chilled Glycol in/out -1/-5°C; cooling water in/out 30/35°C; | |||||||||||||
2.This series of units used in low temperature conditions,25% ethylene glycol to be used as a refrigerant such as antifreeze; |
|||||||||||||
3.Power supply: 3P-380V-50HZ;with voltage allowance ±10%,voltage dif between the phase lines±2%; | |||||||||||||
4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need; | |||||||||||||
5.There may be Changes for improvement without notice, confirm always before your order. |
Introduction:
a. The LSLG series screw compressor chillers is the leading products manufactured by LVTE AIR CONDITIONING Company;
b. The products can provide 7-20°C chilled water, cooling capacity ranging from 50KW to 4000KW;
c. Feature high EER, low noise level, easy operation and maintenance; with more than 40 kinds of models;
d. This series of products is applicable to the industrial process cooling and air conditioning systems.
LSLG SERIES LOW TEMPERATURE SCREW COMPRESSOR WATER CHILLER
SYSTEM FEATURES:
SYSTEM CONTROL:
SAFETY PROTECTION:
1.Discharge check value:it prevents the discharged gas from going back after the compressor stops. |
||||||
2.Phase lack protection:It protects the compressor for over high voltage, voltage dificiency, and phase lack. |
||||||
3.Direction protection:It protects the compressor from damage resulted from Counter direction run. |
||||||
4.Oil heater: It heats the oil before the unit start, keep the good lubrication for the unit before it runs. |
||||||
5.Overheat protection inside the motor of the compressor: It protects the compressor from burning down for too high coil |
||||||
temperature for overload, or abnormal run condition. |
|
|
|
|
|
|
6.High&low pressure protection:It protects the compressor and system against extreme run condition and trouble. |
||||||
Freezing protection:It protects the unit form too low temperature of the water out, freezing may occerat some place, resulting |
||||||
in freezing breaking of the evaporator. |
|
|
|
|
|
|
7.Water flow protect:It protects the unit from run without water flow. |
|
|
||||
8.High temperature of chilled water protection: It works to protect the compressor in case that the load is too large, the temperature of chilled water is too high. It may result in compressor failure without this protect in the case. |
||||||
|