Brand Name: LYTTE, OEM, ODM
Model Number: LTLS SERIES
Place of Origin: Shandong, China (Mainland)
LTLS Series High Efficiency Industrial Water Cooled Chiller
with Screw Compressor
Features of Industrial Water Cooled Chiller
1.30 sizes available ranging from 100 kW to 2000 kW cooling capacity, with heat recovery and low
temperature output;
2.Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.
3. Semi-hermetic screw compressor for all models. Each compressor is equipped with a crankcas
heater and a thermal overload cut-out, the screw compressor is also complete with a built-in electronic
protection with temperature sensor located directly in the motor winding and on discharge line.
4.The refrigerant circuit is complete with sight glass, filter drier, high and low pressure gauges, solenoid
valve, direct expansion valve, high and low pressure switch.
5.Shell and tube dry expansion type condenser, factory insulated with flexible close cell material.
6.The electric panel consists of compressor breaker, compressor contactor, phase sequence relay,
control circuit breaker,microprocessor control with function display.
7.LCD display, touch screen control panel as standard.
8.Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system.
9.For the units with semi-hermetic screw compressor, an infinitely variable capacity control system that is
capable of exactly matching the demand requirement of the system is to be supplied. This system is to provide precise and stable control of supply water temperamture over the complete range of operating conditions.
Model Specification of Industrial Water Cooled Chiller
LT L S---30 W(R) S L(G)
Notes:LT--LVTE Company Products Code
L--Screw Compressors
S--Chiller, Cooling Only
30--Compressor HP
W--Water Cooled
R--With Heat Recovery
S--Single Compressor
L(G)--Chiller Water(Glycol Water) Output Temperature;
L:Glycol Water in/out -1°C/-5°C; G-Glycol Water in/out -11°C/-15°C;None:Chilled Water In/out 12°C/7°C
Safety Protections of Industrial Water Cooled Chiller
1.Discharge check value:it prevents the discharged gas from going back after the compressor
stops.
2.Phase lack protection:It protects the compressor for over high voltage, voltage dificiency, and phase lack.
3.Direction protection:It protects the compressor from damage resulted from Counter direction
run.Oil heater: It heats the oil before the unit start, keep the good lubrication for the unit before
it runs.
4.Overheat protection inside the motor of the compressor: It protects the compressor from burning down for too high coil temperature for overload, or abnormal run condition.
5.High&low pressure protection:It protects the compressor and system against extreme run condition and trouble.
6.Freezing protection:It protects the unit form too low temperature of the water out, freezing may occerat some place,resulting in freezing breaking of the evaporator.
7.Water flow protect:It protects the unit from run without water flow.
8.High temperature of chilled water protection: It works to protect the compressor in case that the load is too large,the temperature of chilled water is too high. It may result in compressor failure without this protect in the case.
Technical Data of Industrial Water Cooled Chiller
1.LTLS-W(R)S(D) Series Water Cooled Chiller
-Semi-hermetic Screw Compressors Units;
-Most used for Central Air Conditioning Cooling System;
-Evaporator Chiller Water Inlet/Outlet Temperature: 12°C/7°C;
ondenser Cooling Water Inlet/Outlet Temperature: 30°C/35°C;
-Heat Recovery is an optional.
Model Details:
-Single Compressor Unit Model: LTLS-30W(R)S to LTLS-200W(R)S
(Capacity 100KW-823.6KW/30Tons-250Tons)
-Double Compressors Unit Model: LTLS-60W(R)D to LTLS-400W(R)D
(Capacity 200KW-2000KW/60Tons-500Tons)
1.1Specifications of LTLS Series Water Cooled Screw Comperssor Chillers
(Single Compressor Model)
1.2 Specifications of LTLS Series Water Cooled Screw Comperssors Chillers
(Double Compressors Model)
2. LTLS-WS(D)L Series Water Cooled Low Temperature(-5°C) Chiller
-Semi-hermetic Screw Compressors Units;
-Without Heat Recovery most used for Industry Cooling System;
-Condenser
Chilled Glycol(25%) Water -Evaporator Inlet/Outlet Temperature: -1°C/-5°C;
Cooling Water Inlet/Outlet Temperature: 30°C/35°C.
Model Details:
-Single Compressor Unit Model: LTLS-30WSL to LTLS-200WSL
(Capacity 50KW-500KW/15Tons-150Tons)
-Double Compressors Unit Model: LTLS-60WDL to LTLS-400WDL
(Capacity 110KW-1000KW/30Tons-300Tons)
2.1Specifications of LTLS Series Water Cooled Screw Comperssors
Low Temperature(-5°C)Chillers (Single Compressor Model)
2.2Specifications of LTLS Series Water Cooled Screw Comperssors
Low Temperature(-5°C)Chillers (Double Compressors Model)
3. LTLS-WS(D)G Series Water Cooled Low Temperature(-15°C) Chiller
-Semi-hermetic Screw Compressors Units;
-Without Heat Recovery most used for Industry Cooling System;
-Condenser
Chilled Glycol(45%) Water -Evaporator Inlet/Outlet Temperature: -11°C/-15°C;
Cooling Water Inlet/Outlet Temperature: 30°C/35°C.
Model Details:
-Single Compressor Unit Model: LTLS-30WSG to LTLS-200WSG
(Capacity 40KW-350KW/10Tons-100Tons)
-Double Compressors Unit Model: LTLS-60WDG to LTLS-400WDG
(Capacity 80KW-700KW/20Tons-200Tons)
3.1Specifications of LTLS Series Water Cooled Screw Comperssors
Low Temperature(-15°C)Chillers (Single Compressor Model)
3.2 Specifications of LTLS Series Water Cooled Screw Comperssors
Low Temperature(-15°C)Chillers(Double Compressor Model)
Photos of Industrial Water Cooled Chiller