Brand Name: andwin
Model Number: WPBZ-003/L
Place of Origin: Jiangsu, China
Technical data | model | ||||||||||||
WPBZ-003/L | WPBZ-004/L | WPBZ-005/L | WPBZ-007/L | WPBZ-010/L | WPBZ-015/L | WPBZ-020/L | WPBZ-025/L | WPBZ-030/L | WPBZ-040/L | WPBZ-050/L | |||
Compressor model |
2DES-3 | 2CES -4 |
4FES -5 |
4DES-7 | 4VES-10 | 4PES -15 |
4NES-20 | 4HE -25 |
4GE -30 |
6GE -40 |
6FE -50 |
||
Titular ref.capacity (W) |
6333 | 7863 | 8900 | 13600 | 16567 | 23715 | 28900 | 37485 | 43010 | 64515 | 76415 | ||
Compressor rated input power (KW) |
2.2 | 3.0 | 3.7 | 5.4 | 7.35 | 11.0 | 14.7 | 18.37 | 22.0 | 29.4 | 36.75 | ||
Refrigerant |
R22 | ||||||||||||
Power |
380V-3PH-50HZ | ||||||||||||
Compressor rated input current (A) |
37..00 | 44.2 | 62.2 | 82.4 | 99.0 | 132.0 | 158.0 | 193.0 | 220.0 | 323.0 | 404.0 | ||
Compressor max. Continuous current (A) |
7.8 | 9.4 | 10.8 | 15.9 | 21.0 | 31.0 | 37.0 | 45.0 | 53.0 | 78.0 | 92.0 | ||
Power of crankcase heater (W) |
0-120 | 0-120 | 0-120 | 0-120 | 100 | 100 | 100 | 140 | 140 | 140 | 140 | ||
Range of evaporating temperature (ºC) |
0~ -20(ºC) (If below -15 ºC evaporating temperature, Need to take additional cooling or limitation of suction temperature and other measures) |
||||||||||||
Cold room temperature (ºC) |
+12~-10(ºC) |
Technical data | model | ||||||||
WPBZ-003/L | WPBZ-004/L | WPBZ-005/L | WPBZ-008/L | WPBZ-010/L | WPBZ-015/L | WPBZ-020/L | WPBZ-030/L | WPBZ-040/L | |
Compressor model |
4FES -3 |
4EES -4 |
4DES -5 |
4TES -9 |
4PES-12 | 4HE -18 |
4GE -23 |
6GE -34 |
6FE -44 |
Compressor rated input power (KW) |
2.2 | 2.94 | 3.67 | 5.88 | 7.35 | 11.02 | 14.7 | 22.0 | 29.4 |
Refrigerant |
R22/R404A/R507A/R134A | ||||||||
Power |
380V-420V-3PH-50HZ | ||||||||
Range of evaporating temperature (ºC) |
-5~ -40(ºC) | ||||||||
Cold room temperature (ºC) |
-10~ -35(ºC) (When the evaporation temperature is less than -20 ºC, Consideration should be given to take additional cooling or suction temperature or spray liquid cooling measures such as restrictions) |
Technical data | model | |||||||||||
FPBZ-003/L | FPBZ-004/L | FPBZ-005/L | FPBZ-007/L | FPBZ-010/L | FPBZ-015/L | FPBZ-020/L | FPBZ-025/L | FPBZ-030/L | FPBZ-040/L | FPBZ-050/L | ||
Compressor model | 2DES-3 | 2CES -4 |
4FES -5 |
4DES-7 | 4VES-10 | 4PES -15 |
4NES-20 | 4HE -25 |
4GE -30 |
6GE -40 |
6FE -50 |
|
Titular ref.capacity (W) |
5840 | 7225 | 8245 | 13600 | 15504 | 22270 | 27115 | 35360 | 40545 | 60775 | 72165 | |
Compressor rated input power (KW) |
2.2 | 3.0 | 3.7 | 5.4 | 7.35 | 11.0 | 14.7 | 18.37 | 22.0 | 29.4 | 36.75 | |
Refrigerant | R22 | |||||||||||
Power | 380V-3PH-50HZ | |||||||||||
Compressor rated input current (A) |
37..00 | 44.2 | 62.2 | 82.4 | 99.0 | 132.0 | 158.0 | 193.0 | 220.0 | 323.0 | 404.0 | |
Compressor max. Continuous current (A) |
7.8 | 9.4 | 10.8 | 15.9 | 21.0 | 31.0 | 37.0 | 45.0 | 53.0 | 78.0 | 92.0 | |
Power of crankcase heater (W) |
0-120 | 0-120 | 0-120 | 0-120 | 100 | 100 | 100 | 140 | 140 | 140 | 140 | |
Power of condensing fan motor (W) |
90x2 | 120x2 | 120x2 | 120x2 | 120x4 | 120x4 | 370x2 | 250x4 | 250x4 | 550x3 | 750x3 | |
Fan Motor working current (A) |
0.20x2 | 0.30x2 | 0.26x2 | 0.26x2 | 0.26x4 | 0.26x4 | 0.80x2 | 0.54x4 | 0.54x4 | 1.2x3 | 1.6x3 | |
Range of evaporating temperature (ºC) |
0~ -20(ºC) (When the evaporation temperature is less than -15 ºC, Need to take additional cooling or limitation of suction temperature and other measures) |
|||||||||||
Cold room temperature (ºC) |
+12~-10(ºC) |
Technical data | model | ||||||||
FPBZ-003/L | FPBZ-004/L | FPBZ-005/L | FPBZ-008/L | FPBZ-010/L | FPBZ-015/L | FPBZ-020/L | FPBZ-030/L | FPBZ-040/L | |
Compressor model | 4FES -3 |
4EES -4 |
4DES -5 |
4TES -9 |
4PES-12 | 4HE -18 |
4GE -23 |
6GE -34 |
6FE -44 |
Compressor rated input power (KW) |
2.2 | 2.94 | 3.67 | 5.88 | 7.35 | 11.02 | 14.7 | 22.0 | 29.4 |
Refrigerant |
R22/R404A/R507A/R134A | ||||||||
Power |
380V-420V-3PH-50HZ | ||||||||
Range of evaporating temperature (ºC) |
-5~ -40(ºC) | ||||||||
Cold room temperature (ºC) |
-10~ -35(ºC) (When the evaporation temperature is less than -20 ºC, Consideration should be given to take additional cooling or suction temperature or spray liquid cooling measures such as restrictions) |