Brand Name: Shield
Model Number: TOSHIBA 55E~305E
Place of Origin: Zhejiang, China (Mainland)
VRV Optimized DAIKIN Refnet Joint in Central Air Conditioning
Refrigerant Distribution Coupling VRV Kits
Types for DAKIN, HITACHI, TOSHIBA, MIDEA, FUJITSU, MITSUBISHI, GREE, YORK, MCQVAY etc. are available. All Pipes have been optimized upon original ones, which have greatly inreased the Cost Performace and Smoothness of Refrigerant Flow....
Features of Shield Brand Disperse Pipe:
1, Raw materials: Copper pipe for R410A with high density& pressure and advanced workmanship;
2,Silver brazing with special designed soldering material & Aided welding for inner space, which have guaranteed disperse pipe with durability and no leakage;
3, Shape dimension has optimized from old ones: total length has been shortened, while thickness inreased, especially for TEE parts which has assured the influency of refrigerant; Besides, the improvement of pipe has greatly inreased cost performance;
4,Scrupulous quality control, inspection of raw material, semi-finished products & finished products each pipe has to proceed 6.5MPa pressure test before package. Surface treatment is among No. 1s in domestic
Model |
A |
B |
C |
|
RBM-BY53E |
GAS pipe |
15.9 |
12.7 |
12.7 |
Liquid pipe |
12.7 |
9.6 |
9.6 |
|
Fittings |
Nine fittings for chosing |
|||
RBM-BY103E |
GAS pipe |
22.3 |
19.1 |
19.1 |
Liquid pipe |
15.9 |
12.7 |
12.7 |
|
Fittings |
Fifteen fittings for chosing |
|||
RBM-BY203E |
GAS pipe |
31.8 |
28.7 |
28.7 |
Liquid pipe |
15.9 |
15.9 |
15.9 |
|
Fittings |
Fifteen fittings for chosing |
|||
RBM-BY303E |
GAS pipe |
38.1 |
38.1 |
38.1 |
Liquid pipe |
22.3 |
19.1 |
19.1 |
|
Fittings |
Twenty fittings for chosing |
|||
RBM-BY13E |
GAS pipe |
38.1 |
38.1 |
38.1 |
Liquid pipe |
22.3 |
22.3 |
22.3 |
|
Fittings |
Thirteen fittings for chosing |
|||
RBM-BY55E |
GAS pipe |
15.9 |
15.9 |
15.9 |
Liquid pipe |
9.52 |
9.52 |
9.52 |
|
Fittings |
Four fittings for chosing |
|||
RBM-BY105E |
GAS pipe |
15.9 |
15.9 |
15.9 |
Liquid pipe |
22.3 |
22.3 |
22.3 |
|
Fittings |
Four fittings for chosing |
|||
RBM-BY205E |
GAS pipe |
28.7 |
28.7 |
28.7 |
Liquid pipe |
15.9 |
15.9 |
15.9 |
|
Fittings |
Ten fittings for chosing |
|||
RBM-BY305E |
GAS pipe |
35 |
35 |
35 |
Liquid pipe |
22.3 |
22.3 |
22.3 |
|
Fittings |
Eleven fittings for chosing |
|||
RBM-BT14E |
GAS pipe |
31.8 |
28.7 |
OD28.5 |
Liquid pipe |
T19.1 |
T19.1 |
T19.1 |
|
Liquid pipe |
T12.7 |
T12.7 |
T12.7 |
|
Fittings |
Eight fittings for chosing |
|||
RBM-BT24E |
GAS pipe |
38.1 |
38.1 |
OD31.8 |
Liquid pipe |
T28.7 |
T28.7 |
T28.7 |
|
Liquid pipe |
T22.3 |
T22.3 |
T22.3 |
|
Fittings |
Thirteen fittings for chosing |