Brand Name: LNEYA
Model Number: SUNDI-555
Place of Origin: Jiangsu, China (Mainland)
Brilliant 4 inch, 7 inch, 10 inch TFT touch screen with graphic display -50 up to 250 degree
Typical Applications
Reactor Systems Autoclaves
Pilot Systems
Mini Plant Systems
Scale up for Operational Development
Double wall reactors
Advanced-Flow Reactors
Distillation Systems
Material Testing
Combinational Chemistry
Semiconductor Industry
Vacuum Chambers
Structure design
A fully closed piping design, high efficiency plate heat exchanger used to reduce the demand for the thermal fluid utilization while providing the system to achieve the rapid ups and downs in temperature The whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical connection, regardless of the temperature is a high temperature or low temperature, the tank temperature is limited to 60℃. Therefore, during the process the risk of imbibing and volatilization of the heat conducting medium is reduced. There following advantages for the user.
Technical Parameters:
Model |
SUNDI-525W N
|
SUNDI-535WN
|
SUNDI-555W SUNDI-555 |
SUNDI-575W SUNDI-575 |
SUNDI-5A10W SUNDI-5A10 |
SUNDI-5A15W
|
|
Temperature range ℃ |
-50℃~250℃ |
-50℃~250℃ |
-50℃~250℃ |
-50℃~250℃ |
-50℃~250℃ |
-50℃~250℃ |
|
Control Mode |
Feed forward PID + Our special dynamic control calculation, PLC controller |
||||||
Temp. control |
Option: process temperature control or jacket oil temperature control |
||||||
Temp. difference |
Set or control the temperature difference between jacket oil and raw material process |
||||||
Program Editor |
20 programs, each program can edit 45 steps. |
||||||
Communication protocol |
MODBUS RTU Protocol, RS 485 Interface |
||||||
Temperature feedback |
Heat-conducting medium: PT100 Raw material process: PT100 |
||||||
Temp. accuracy |
±1℃ |
±1℃ |
±1℃ |
±1℃ |
±1℃ |
±1℃ |
|
Heating power |
2500W |
3500W |
5500W |
7500W |
10000W |
15000W |
|
Cooling capacity |
250℃ |
2000W |
3500W |
5500W |
7500W |
10000W |
15000W |
100℃ |
2000W |
3500W |
5000W |
7000W |
10000W |
15000W |
|
20℃ |
2000W |
3500W |
5000W |
7000W |
10000W |
15000W |
|
0℃ |
1800W |
3000W |
5000W |
7000W |
10000W |
15000W |
|
-20℃ |
850W |
1500W |
2850W |
4200W |
6000W |
11000W |
|
-40℃ |
250W |
450W |
900W |
1500W |
2000W |
3750W |
|
Circulation pump |
Max20L/min 2BAR |
Max20L/min 2BAR |
Max35L/min 2BAR |
Max50L/min 2.5BAR |
Max50L/min 2.5BAR |
Max110L/min 2.5BAR |
|
Compressor |
Tecumseh |
Copeland |
Copeland |
Copeland |
Copeland |
Copeland |
|
Expansion valve |
Danfoss |
Danfoss |
Danfoss |
Danfoss |
Danfoss |
Danfoss |
|
Oil separator |
Emerson |
Emerson |
Emerson |
Emerson |
Emerson |
Emerson |
|
Operation Panel |
7-inch color touch screen controller,temperature curve record,data export to excel format. |
||||||
Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. |
|||||||
Closed |
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. |
||||||
Refrigerant |
R-404A |
R-404A |
R404A |
R404A |
R404A |
R404A |
|
Connection size |
DN-15 or M24*1.5 |
DN15 or M30*1.5 |
DN20 or M30*1.5 |
DN20 or M30*1.5 |
DN20 or M30*1.5 |
DN-25 M38*1.5 |
|
Water-cooled type W (cooling water at 20℃) |
600L/H 1.5bar~4bar |
800L/H 1.5bar~4bar |
1500L/H 1.5bar~4bar |
1800L/H 1.5bar~4bar |
2600L/H 1.5bar~4bar |
3200L/H 1.5bar~4bar |
|
Dimension |
water-cooled |
400*600*1050 |
400*600*1050 |
600*700*1150 |
600*700*1150 |
600*700*1150 |
700*700*1250 |
air-cooled |
|
|
550*680*1450 |
620*700*1450 |
700*700*1750 |
|
|
Weight |
water-cooled |
160kg |
185kg |
245kg |
285kg |
320kg |
360kg |
air-cooled |
|
|
280kg |
320kg |
360kg |
|
|
Power |
AC 220V 50HZ 4.5kW (max) |
AC 380V 50HZ 6.A5kW (max) |
AC 380V 50HZ 9kW (max) |
AC 380V 50HZ 12.5kW (max) |
AC 380V 50HZ 16.5kW (max) |
AC 380V 50HZ 24kW (max) |
|
Case material |
SUS 304 |
SUS 304 |
SUS 304 |
SUS 304 |
SUS304 |
SUS304 |
|
Optional |
Optional Ethernet interface, configure PC operating software |
||||||
Optional |
Optional outside touch screen display controller (separated), the communication line distance is 10 meter. |
||||||
Optional power |
220V 60HZ three-phase, 440V~480V 60HZ three-phase |
The images of factory:
2015 Corning Reactor and its Ancillary Equipment Technology Exchange Meeting
2015 Corning Reactor and its Ancillary Equipment Technology Exchange Meeting
During March 26th~27th of 2015, our company, the main ancillary equipment supplier of Corning Advanced-FlowTM glass reactors, was invited to attend " 2015 corning reactor technology exchange meeting" by Corning
company,a fortune 500 businesses in the United States. The meeting was held in famous Shangri-la hotel in Changzhou.
The general manager of Wuxi guanya refrigeration technology company shared select reactors according to heat
transfer and heat exchange, refrigeration and heating temperature control system and its advantages, the different
temperature controleffect between dynamic temperature control system applied to Corning Advanced-FlowTM glass reactor and other normal reactors and display the video of dynamic temperature control effect.
The meeting was a big success!
Upgrade Notice For Dynamic Temperature Control System
The images of certificate: