Brand Name: DERON
Model Number: DE-27W/CR
Place of Origin: Guangdong, China (Mainland)
DERON air to water heat pump, air source heat pump
Model: DE-27W/CR
This series of Air Source Heat Pump with heating &cooling function is specially designed for house heating& sanitary hot water for bathroom in cold areas, and cooling& sanitary hot water in the hot weather.
1.Five running modes: Cooling + hot water, Heating + hot water, Single cooling, Single heating, Single hot water
2.It can be work in -10°C~45°C
3.Hot water output temp. up to 60°C.
4.refrigerant: R410A
5.Auxiliary electric heater is optional as a back up heater.
6.Comprehensive protection
7.Anti-corrosion case: coating case or stainless steel case; all case with stainless steel bolts and nuts.
8.Every heat pump must be tested to guarantee the good quality and feature before package.
Model |
DE-27W/CR |
|||
Power supply |
(V/ph/Hz) |
380/3/50 |
||
Single cooling mode |
*Cooling capacity |
(kw) |
7.5 |
|
(BTU) |
25589 |
|||
*Rated power input |
(kw) |
2.8 |
||
*Test condition |
*Ambient temp.(Dry Bulb/Wet Bulb): 35°C /24°C, Water temp.(in/out): 12°C/7°C. |
|||
Single hot water mode |
**Heating capacity |
(kw) |
11.2 |
|
(BTU) |
38213 |
|||
**Rated power input |
(kw) |
2.7 |
||
**Test condition |
**Ambient temp.(Dry Bulb/Wet Bulb): 20°C /15°C, Water temp.(in/out): 15°C/55°C. | |||
Single heating mode |
***Heating capacity |
(kw) |
8 |
|
(BTU) |
27295 |
|||
***Rated power input |
(kw) |
2.7 |
||
***Test condition |
**Ambient temp.(Dry Bulb/Wet Bulb): 7°C /6°C, Water temp.(in/out): 40°C/45°C. |
|||
Cooling +hot water mode |
****Cooling capacity |
(kw) |
6.8 |
|
(BTU) |
23201 |
|||
****Heating capacity |
(kw) |
9.8 |
||
(BTU) |
33436 |
|||
Refrigerant |
R410A |
|||
Compressor |
(type) |
Scroll |
||
(number) |
1 |
|||
Fan |
(type) |
Axial flow type with Nylon fan blade |
||
(discharging) |
Horizontal |
|||
(number) |
1 |
|||
(air flow)(m3/h) |
3500 |
|||
Evaporator |
(type) |
Aluminium/Cu lamellar tube evaporator |
||
Condenser (heat exchanger) |
(type) |
Coaxial coil heat exchanger (Copper Tube-in- Steel Tube) |
||
Throttling device |
Emerson thermal expansion valve |
|||
Controller |
Indoor Digital Controller |
|||
Required cool water flow rate |
(m3/h) |
1.5 |
||
Required hot water flow rate |
(m3/h) |
2 |
||
Water connection |
G1" |
|||
Noise |
dB(A) |
≤56 |
||
Max. current |
(A) |
7.5 |
||
Level again electric shock |
I |
|||
Water proof |
IPX4 |
|||
Max. water temp. |
(°C) |
60 |
||
Operation temp. range |
(°C) |
-10-45 |
||
Net weight |
(kg) |
125 |
||
Net size |
(mm) |
755X545X1490 |