Brand Name: LYTTE or OEM
Model Number: LTWF
Place of Origin: Shandong, China (Mainland)
Trane Air Cooled Chiller Cooling Chiller
for Air Conditioner
Two Kinds of Models:Air Cooled Water Chiller/Air to Water Chiller
1. Cooling Condition: Chilled Water In/Out 12°C/7°C;Ambient 35°C
Models: LTWF03AS-40AD
Cooling Capacity: 8KW-120KW
2.Cooling Condition: Chilled Glycol in/out -1/-5°C; Ambient 35°C
Models: LTWF03ASL-40ADL
Cooling Capacity: 4.7KW-61.6KW
AIR IS USED FOR THE COOLING NAD HEATING RESOURCE
NO POLLUTION AND ENERGY SAVING,PURE GREEN PRODUCTS
Competitive Advantage:
1. Using inexhaustible source of air as cold and heat resources by electric drive, so that low-grade energy can change into high-grade energy. No pollution, save water, and also avoid water sources pollution.
2. Adopt microcomputer control system, it has display, control and protect functions. Human interface operation, control unit operating status at any time.
3.No cooling tower, cooling water pipeline and the engine room, easy installation, civil engineering investment; no fuel, fully automatic operation, running a small additional cost; unit processor connected with central air conditioning, summer cooling and winter heating, heating do not need a separate heating station.
4. Heat recovery technology, it realizes part water cooled with a water-cooled unit high efficiency features, both for free hot water from using waste heat, waste heat emissions reduced directly to protect the environment and improve unit efficiency and reduce the failure rate, extend working life.
5. Low noise axial flow fan, compressor with vibration damping devices, low noise.
Unit modular design which can meet any combination of sizes, transportation, installation and convenient maintenance, adopts unique pipeline design to ensure the crew in winter temperature -15°C still be able to run.
6. Application areas: Apply for building with 300-15000sqm., particularly urban downtown lots or water stress areas; if they are not allowed or difficult to install cooling tower boiler, it is the best choice. Also for noise environment and old air conditioning renovation projects, and provide cold water for process air conditioning
LVTE CENTRAL AIR CONDITIONER BUILD THE MOST ENERGY-EFFICIENT COMFORTABLE WORLD
Note:
Refrigeration standard conditions: 12°C/7°C input/output water; ambient tem. 35°C
Heating standard conditions: 40°C/45°C input/output water; ambient tem. 7°C
SYSTEM DIAGRAM
WE WELCOME TO ESTABLISH BUSINESS WITH US
LUTE Heat pump central air conditioning system
A. LUTE brand---china famous brand
B. Adopt import advanced American technology
C. Using world famous accessories as compressor etc
D. Designed by ourselves, own tens of design patents
E. Most energy saving and lowest running charge
F. Adopting environmental protection refrigerant as R134A, R22, R407C etc
G. Advocacy the government Energy-saving and emission-reduction policy
H. Apply for kinds of buildings for cooling, heating and making hot water
I.Most Advanced Testing and Inspection System and We Promise that Each Unit will Be Tested Over 48hours to Be Proved Qualified
J. We Solemn Promise Quick After Service and Very Priced with Highest Quantity
Model Details of Air Cooled Chiller
1. Design Cooling Condition: Chilled Water In/Out 12°C/7°C;Ambient 35°C
Models: LT03AS-40AD Cooling Capacity: 8KW-120KW
-Hermetic Scroll Compressors
-Tube in Tube Type Heat Exchanger for Evaporator
-V Type Fin Air Cooled Condenser
-Water Pump and Water Tank are an optional to built in the chiller
-Chilled Water Inlet/Outlet Temperature 12°C/7°C,Ambient 35°C
-Mostly Used for Central Air Conditioning Cooling
Technical Data
Remark: 1.Colling Condition: Chilled water in/out 12/7°C;Ambient Temperature 35°C;
2. Suitable chilled water temperature: 7-25°C;
3. Power supply: 3P-380V-50HZ; with voltage allowance ±10%, voltage dif between the phase lines±2%;
4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;
5. There may be Changes for improvement without notice, confirm always before your order.
Remark: 1.Colling Condition: Chilled water in/out 12/7°C;Ambient Temperature 35°C;
2. Suitable chilled water temperature: 7-25°C;
3. Power supply: 3P-380V-50HZ; with voltage allowance ±10%, voltage dif between the phase lines±2%;
4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;
5. There may be Changes for improvement without notice, confirm always before your order.
Low Temperature Models:
2.Cooling Condition: Chilled Glycol in/out -1/-5°C; ambient 35°C
Models: LT03ASL-40ADL Cooling Capacity: 4.7KW-61.6KW
-Hermetic Scroll or Semi-hermetic Piston Compressors
-Tube in Tube Type Heat Exchanger for Evaporator
-V Type Fin Air Cooled Condenser
-Water Pump and Water Tank are an optional to built in the chiller
-Chilled Glycol Inlet/Outlet Temperature -1°C/-5°C, Ambient 35°C
-Mostly Used for Industrial Processing Cooling
Remark :1.Designed Condition:Chilled Glycol in/out -1/-5°C; ambient 35°C;
2.This series units used in low temperature conditions, 25% ethylene glycol to be used as a refrigerant;
3.Power supply: 3P-380V-50HZ;with voltage allowance ±10%,voltage dif between the phase lines±2%;
4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;
5.There may be Changes for improvement without notice, confirm always before your order.