Brand Name: HD
Model Number: DL-12
Place of Origin: Jiangsu, China (Mainland)
Application :
This element DL-12 capillary sensor is used to remotize the temperature sensor of a standard thermostatic
head in order measure better room temperature.
Technical requirements :
Model | DL-12 |
Temperature range | 5...... 26 C |
Extension | 0.22 mm/ K |
Reference size X | 32.35+/-0.3 mm |
Thermal bulb | Nickel-plated |
Capillary length | 2000 mm or customized |
Under pressure 6KG , 20 degree C , "X " =32.35±0.3 mm .
Under pressure 6KG , 5-26 degree C , stroke =4.62±0.23 mm . 0.22 ± 5%mm/k
Under pressure 12KG , bellows and bulb both can not have deformation .